864 Fibers. <20mm. Zero Congestion.

Fúxī and Longma High-Density Cable Assemblies — Precision-scheduled builds and agile-response braids for hyperscale backbones. Mini fan-out legs. Custom counts to 6912F.

288F–864F Standard

6912F Custom

VSFF In Stock

01

Procurement

One Optical Performance.
Two Business Rhythms.

01 Scheduled Build

Fúxī

The Scheduled Build

  • For data center operators with multi-quarter construction timelines
  • Precision-manufactured to exact port counts, lengths, and polarity maps
  • Factory-terminated, pre-tested, shipped to site on the day the rack is ready
  • No field splicing. No last-minute cable cutting. No inventory bloat.
02 Emergency Response

Longma

The Emergency Response

  • For operators who hit density faster than forecast
  • Braided armored assemblies, pulled from existing Low density cables at stock and rapid-braided to spec
  • Agile response: specification today, shipment this week
  • Same IL/RL performance as Fúxī. Different procurement velocity.
02

Features

Main Features

01

Density in Diameter
864F in 17.0 mm OD

Competitors need 20+ mm for 576F. We deliver 864F in 17.0 mm — smaller outer diameter, higher fiber count, easier conduit fill. Custom constructions to 3456F and 6912F confirmed with design and termination capability.

02

Mini Fan-Out
1.6 mm Legs. No Airflow Block.

Traditional 2.0 mm fan-out legs create cable nests that obstruct rack airflow and complicate MACs. Our assemblies use 1.6 mm legs — 36% less bulk at the patch field. While competitors are still ramping VSFF, ADTEK has assemblies in stock today.

03

Bend-Insensitive Standard
G.657.A1/A2. Every Count.

Bend-insensitive fiber is non-negotiable in dense patch environments. All standard assemblies use G.657.A1/A2. SMF-28 and options available for specific link budgets. The fiber is not an upgrade — it is the baseline.

04

Asymmetric & Super-Trunk
Break Out on Your Terms

Standard symmetric breakout: 864F trunk to 144 × 6F legs. Asymmetric options: 864F to 96 × 8F + 48 × 4F. Super-Trunk: 6912F main cable to multiple 864F sub-trunks. Factory-terminated and polarity-verified. No field fan-out kits.

03

Specifications

Technical Specifications

Parameter Specification
Standard Fiber Counts 288F, 576F, 864F
Custom Fiber Counts 1728F, 3456F, 6912F
Outer Diameter (864F) 17.0 mm
Fan-Out Leg Diameter 1.6 mm (Custom), 2.0 & 2.3 mm (standard)
Fiber Types G.657.A1/A2 (standard), SMF-28 (optional)
Jacket Options LSZH, Plenum, CPR
Connector Options MPO/MTP-8/12/16/24, MMC-16/24 SN-MT, LC, SC
Polarity Management Method A/B/C, Universal, Custom mapping
Testing 100% IL/RL/3D tested
Insertion Loss (Typical) ≤0.35 dB (MPO-12), ≤0.20 dB (Low Loss grade)
Return Loss ≥60 dB (UPC), ≥65 dB (APC)
04

Scenarios

Deployment Scenarios

A

Fúxī for the Long Plan

A 500-rack AI cluster with a 12-month rollout. Fúxī assemblies are manufactured to the exact port count and length specification, tested at the factory, and delivered in phased shipments aligned to your rack-activation schedule. No excess cable. No emergency air freight.

B

Longma for the Surge

Your training cluster grew from 2,000 to 5,000 GPUs in one quarter. The original trunk design is now at 80% capacity. Longma braided assemblies are pulled from stock or rapid-manufactured to bridge the gap — same optical performance, different procurement timeline.

C

One Trunk. Many Destinations.

A 1728F Super-Trunk enters the MDA. It breaks out to 144 × 12F legs for standard patching, 48 × 4F legs for storage nodes, and 24 × 2F legs for management. All factory-terminated, all polarity-verified, all labeled. The field technician connects. They do not construct.

05

Compliance

Standards Alignment

TIA-568-C.3IEC 60794Telcordia GR-20RoHSREACH

Match Your Cable to Your Timeline

Request a Fúxī sample for your scheduled build, or a Longma braid for your emergency expansion. Discuss custom Super-Trunk counts and asymmetric breakout configurations with our engineering team.