Agility at Scale. Density Without Delay.

Fúxī & Longma HD Cable Assemblies — From 288F to 864F (and custom 6,912F super-trunks), with VSFF assemblies available today.

Choose Fúxī for scheduled monolithic precision, or Longma for braided agility—delivered in days versus weeks. No MOQ, no supply chain games.

864F Standard

6,912F Custom

VSFF Ready

Days vs. Weeks

Fúxī (Monolithic): Factory-cabled, scheduled production

Fúxī (Monolithic): Factory-cabled, scheduled production, maximum density. Standard counts (288/576/864F), several-week lead time, permanent infrastructure. Longma (Braided): Semi-automated braiding over sub-units, days-not-weeks delivery. Any fiber count (144F–864F+), field-modifiable, experimental topologies. Both share identical fiber specs and assemblies —performance parity, logistics flexibility. Whether you need certified plant precision or crisis-response agility, the same optical excellence applies.

3x Density with SN-MT & MMC

While competitors are still ramping, ADTEK has VSFF (Very Small Form Factor) assemblies in stock today. SN-MT and MMC provide triple the port density per rack unit versus legacy MPO/LC—critical for 800G and emerging 1.6T architectures. Paired with our ultra-slim 1.6mm fan-out legs, VSFF enables true high-density spine-leaf without the assemblies bottleneck. Available for both Fúxī and Longma series.

Pristine End-Faces After the Blow

AI switches are thermal choke points. Our 1.6mm VSFF fan-out legs reduce cross-sectional obstruction by 71.5% versus legacy 3.0mm cables based on geometric calculation—enabling improved laminar airflow through 1RU switch exhaust paths. The theoretical advantage is clear: 36 cables occupying just 72.4 mm² versus 254.5 mm² for traditional cabling. Less obstruction, lower fan power, reduced cooling OPEX. Designed for thermal optimization, engineered for AI density.

Custom Super-Trunks to 6,912F

Standard portfolio covers 288F–864F. Beyond that, our engineering team designs custom Super-Trunks—aggregating multiple 864F rollable ribbon sub-units into managed pathways of 3,456F or 6,912F. We’ve validated the assemblies processes and trained our design engineers for extreme density. Available as custom capability upon request for next-generation AI core backbones where standard products don’t exist. Note: Currently evaluating cable producers for 3,456F/6,912F; design and termination capability confirmed.

Technical Specifications - Full Data Edition

Technical Specifications

STANDARDS: ISO 11801, EN 50173, IEC 60332-1, IEC 61034-2, IEC 60754-2, ROHS3, EN 50575/13501-6

Series Comparison

Attribute Fúxī Series Longma Series
Construction Monolithic factory-cabled Braided sleeve over sub-units
Standard Counts 288 / 576 / 864F 144F–864F+ (any multiple)
Lead Time Several weeks (scheduled) Days vs. weeks (stock dependent)
Flexibility Permanent infrastructure Field-modifiable, mixed media capable
Best For Greenfield, certified plant, max density Brownfield, crisis response, experimental
Fiber Types Rollable Ribbon (200μm) or Micro-Structure (250μm) Sub-units: Rollable or Micro-Structure
assemblies MTP/MPO (12/16/24), MMC, SN-MT, LC Same as Fúxī
OD (864F) 17.0mm (Rollable) / 25.2mm (Micro) ~19–29mm (braid adds 2–4mm)

Rollable Ribbon (AI Clusters)

Fiber Count OD Weight Min Bend Tensile
288F <10.9mm 95 kg/km 109mm 2,670N
576F <15.0mm 239 kg/km 150mm 2,670N
864F <17.0mm 358 kg/km 170mm 4,400N

Micro-Structure (Ruggedized)

Fiber Count OD Weight Min Bend Tensile
288F <16.2mm 178 kg/km 162mm 4,400N
576F <22.0mm 405 kg/km 220mm 4,400N
864F <25.2mm 564 kg/km 252mm 4,400N

VSFF assemblies Availability

Type Count Dimensions Availability
SN-MT 16-fiber (8 duplex) 4.2mm width Stock (both series)
MMC 16-fiber (multi-row) 6.25mm x 4.8mm Stock (both series)
MTP/MPO-16 16-fiber Standard In stock
MTP/MPO-24 24-fiber Standard In stock

Environmental Ratings

Parameter Specification Standard
Flame Retardance IEC 60332-1 (single vertical), IEC 60332-3-24 available
Smoke Density IEC 61034-2 (>60% light transmittance)
Halogen-Free IEC 60754-2 (pH >4.3, conductivity <10μS/mm)
CPR Rating Euroclass Cca-s1a-d1-a1 (EN 50575/13501-6); B2ca available

Deployment Configurations

Scheduled Precision for Maximum Density

New hyperscale data center, 10,000+ GPU cluster, scheduled build-out. Fúxī delivers maximum density with 17.0mm OD for 864F—smaller than competitors’ 576F offerings. Factory-terminated precision ensures consistent insertion loss for permanent infrastructure. VSFF SN-MT assemblies enable 800G DR8/1.6T spine-leaf architectures without patch panel congestion. Order 6-8 weeks ahead of installation window for coordinated delivery.

Supply Chain Agility in Days

Competitor lead times slipped, cluster expansion delayed, need 576F in days not weeks. Longma’s semi-automated braiding process uses pre-stocked sub-units assembled to order. No MOQ means you can order exactly 432F (not forced into 576F standard). Field-modifiable architecture allows mixed fiber types (SMF-28 + BendBright) in the same assembly. When “time-to-light” matters more than absolute minimum OD, Longma delivers.

Asymmetric Breakouts & Super-Trunks

Research lab testing new spine-leaf variant, need 432F with asymmetric fan-out (288F to Zone A, 144F to Zone B). Or hyperscale backbone requiring 6,912F custom Super-Trunk aggregation. Longma accommodates custom fiber counts, mixed assemblies types on same trunk, and multi-sub-unit aggregation. For extreme density, our engineering team designs 3,456F and 6,912F Super-Trunks using validated assemblies processes—available as custom capability upon request.

top Splicing at the Endpoint

Ready to deploy fiber faster through micro-ducts? Request a SlimRun Jet evaluation kit with SC and LC variants, 1.2mm jetting cable samples, and blowing compatibility guidelines. Our application engineers will validate duct specifications for your specific FTTH infrastructure.